Q: How to solve the abnormal sound of the oil pump in the die-casting machine?

A: The cause of the malfunction:

1. Power supply phase loss

2. Oil pump reverse rotation

3. Oil pump damage

4. The system pressure is too high

Handling method:

1. Check the three-phase power line

2. Swap any two power cables

3. Repair or replace the oil pump

4. Adjust the relief valve to ensure that the system pressure meets the regulations